Cold storage facilities for freezer room cold storage

图片
  Product Description Feature Energy saving , Cold room type Fish storage, seafood cold room , Ice cream storage, Icehouse , customization , etc. Temperature -25°C ~ -5°C, -5°C ~+5°C, customization Cold room panel 150mm / 100mm / 75mm polyurethane cold storage board Cold room door Sliding door and Hinged door both can support. Compressor Brand Bitzer ,Copeland, Danfoss , Maneurop, Refcom and so on Condensing unit XMK Box-type Unit with Scroll compressor , Semi-hermetic unit and customization Air cooler XMK CDB series, IDB series, CS series, ND series Accessories Control box, expansion valve, cold room lamp ,etc Customization accept View of Customer Case  Product Image

Meat refrigerated pork beef cold storage room

图片
  Product Description  Feature Save Power , fast cool , humanized design and power -off protection Cool room type Slaughtering cold storage , Meat Refrigerated , Food's Cold room customization Temperature >= -18°C Cool room panel 150mm / 100mm / 75mm PU panel with two sides color plate Cold room door Sliding door and Hinged door both can support. Compressor Brand Bitzer ,Copeland, Danfoss , Maneurop, Refcom, etc. Condensing unit XMK Box-type Unit with Scroll compressor , Semi-hermetic unit and customization. Air cooler XMK CDB series, IDB series, CS series, ND series Accessories Control box, expansion valve, cold room lamp ,etc Customization accept

What is the difference between direct cooling and air-cooled cold storage

图片
  The meaning of direct-cooling cold storage: the cooling tube of the cold storage evaporator is directly fixed on the storage plate. When the evaporator absorbs heat, the air closer to the cooling tube cools faster, thereby forming natural convection in the co ld storage room , which is gradually realized Integral refrigeration, that is, direct cooling methods, such as common iron row pipes, aluminum row pipes, etc. Air-cooled cold storage means: the cold air generated by the cold storage evaporator is circulated through the fan to force the refrigerating air, so that the cold air is evenly distributed in each compartment of the cold storage to achieve cooling, that is, the cooling method that uses the fan to circulate the cold air. Direct-cooled cold storage Advantages of direct cooling cold storage: 1. Direct cooling type cold storage has simple structure, relatively low failure rate, and low cost resulting in low price. 2. It has a good cooling effect and is...

Signs of normal operation of cold storage room

图片
  Some customers will ask what the state of the cold storage room is during normal operation. Today, I will give you a popular science knowledge about the normal operation of the CBFI cold storage room . 1. There should be no noise in the cylinder, only the normal and regular cold storage sound of the suction valve. 2. The suction temperature of the compressor should be 5-15℃ higher than the evaporation temperature (R22). 3. The condenser cooling water in the cold storage room should be sufficient, the water pressure should be above 0.12mpa, and the water temperature should not be too high. 4. For the new series of products, the reading of the oil pump pressure gauge should be 0.15-0.3mpa higher than the suction pressure 5. There should be no foot heating and frosting on the cylinder wall, and the surface temperature difference should not be greater than 15-20 degrees. For refrigerated or low-temperature systems, frosting of the suction pipe can generally r...

The cold storage's compressor suddenly stops during operation

  Some customers reported that the cold storage room 's compressor stops suddenly during operation some time ago. Now let’s analyze the reason and how to deal with it. 1. The cold storage room effect of air-cooled condenser is poor 【Fault Analysis】 ① The fan is not turned on. To ② The fan motor is damaged. ③ The fan is reversed. ④ The ambient temperature is high (above 40℃). ⑤ The condenser fins are blocked by oil and dust and the air does not circulate. 2. The heat dissipation effect of the cold storage room of the water-cooled condenser is poor ① The cooling water valve is not opened or opened too small, and the inlet water pressure is too low ② The water control valve is out of order. ③ The scale on the wall of the condenser tube is thick. [elimination method] Air-cooled: Use a wire brush to remove surface dust. Water-cooled: Check the cooling water volume. Remove limescale. 3. Too much refrigerant is charged in the system [Fault analysis] Excessive refrigerant causes...